Quan Yu's high-quality Diesel Generator Set 75KW rely on diesel combustion to generate power and drive the generator set. The use of small fuel powered generators can play an emergency role. In case of a power outage, the fuel generator can be started to generate electricity to maintain normal operation.
The diesel engine is mainly composed of the following components and parts: collective components and crankshaft connecting rod mechanism, valve distribution mechanism and intake and exhaust system, diesel engine supply system, cooling system, lubrication system, starting and electrical system, and turbocharging system.
Diesel Generator Set With XG-75GF Cummins Engine |
|||
Overall Size |
Weight |
||
3000(mm)*1200(mm)*1600(mm) |
2100(kg) |
||
Set Type: |
XG-75GF |
||
Standby Power: |
82.5KW/103.125KVA |
||
Prime Power: |
75KW/93.75KVA |
||
Rated Current: |
135(A) |
||
Rated Frequency: |
50(Hz) |
||
Start-up time: |
5~6(s) |
||
Power Factor: |
0.8(Lag) |
||
Rated Voltage: |
400/230(V) |
||
Standard Features |
|||
Engine:DCEC Cummins 6BT5.9-G2/Radiator 50℃max/Fans are driven by belt, with safety guard/24V charge alternator/Dry type air filter, fuel filter, oil filter/Alternator: single bearing alternator/IP23, insulation class H/H/ Main line circuit breaker/Standard control panel/Absorber/muffler/User manual |
|||
Diesel Engine Data |
|||
Manufacturer: |
DCEC Cummins |
||
Model: |
6BT5.9-G2 |
||
Standby Power: |
92KW |
||
Rated Speed: |
1500(r/min) |
||
Cycle: |
4 stroke |
||
Cylinder Arrangement: |
6 in line |
||
Displacement: |
5.9L |
||
Bore and Stroke: |
102*120(mm) |
||
Compression Ratio: |
17.5:1 |
||
Governor Type: |
Electronic |
||
Start battery voltage: |
24V DC |
||
Air Intake System |
|||
Air Intake System: |
Air natural cooled |
||
Max Intake Restriction: |
6.35kPa |
||
Burning Capacity: |
6.48m3/min |
||
Air Flow: |
158m3/min |
||
Exhaust System |
|||
Exhaust Gas Flow: |
16.8m3/min |
||
Exhaust Temperature: |
565℃ |
||
Max Back Pressure: |
10kPa |
||
Fuel System |
|||
Fuel System: |
A model fuel pump |
||
100%( Prime Power) Load: |
210g/kwh |
||
Oil System |
|||
Total Oil Capacity: |
16.4L |
||
Oil Consumption: |
≤0.4g/kwh |
||
Oil Pressure at Rated RPM: |
350kPa |
||
Cooling System |
|||
Cooling Way: |
Water-cooled |
||
Total Coolant Capacity: |
27L |
||
Thermostat: |
82-95℃ |
||
Max Water Temperature: |
104℃ |
||
Alternator Data |
|||
Manufacturer: |
STAMFORD UCI 274C |
||
Excitation Mode: |
Brushless and self- exciting |
||
Number of phase and Access Act: |
3-phase 4-wire |
||
Connecting Type: |
“Y” type connecting |
||
Alternator Capacity: |
100KVA |
||
Alternator Efficiencies: |
95% |
||
Overload: |
(PRP)110% load can run 1h |
||
Protection Level: |
IP23 |
||
Insulation Class, Temperature Rise: |
H/H |
||
Telephone Influence Factor (TIF): |
<50 |
||
THF: |
<2% |
||
Altitude: |
≤1000m |
||
Genset Electrical Performance |
|||
Voltage Regulation: |
≥±5% |
||
Voltage Regulation, Stead State: |
≤±1% |
||
Sudden Voltage Warp (100% Sudden Reduce): |
≤+25% |
||
Sudden Voltage Warp (Sudden Increase): |
≤-20% |
||
Voltage Stable Time (100% Sudden Reduce): |
≤6S |
||
Voltage Stable Time (Sudden Increase): |
≤6S |
||
Frequency Regulation, Stead State: |
≤5% |
||
Frequency Waving: |
≤1.5% |
||
Sudden Frequency Warp (100% SuddenReduce): |
≤+12% |
||
Sudden Frequency Warp (Sudden Increase): |
≤-10% |
||
FrequencyRecoveryTime(100%SuddenReduce): |
≤5S |
||
FrequencyRecoveryTime(Sudden Increase): |
≤5S |
||
The manufacturer reserves the right of technical alteration /change for better improvement without prior notice |
Our low noise gensets (Silent gensets) use shock insulation, sound insulation, and sound absorbing and so on noise reduction measures tomake the noise indexes decreased significantly. The low noise GFD series power station are individed into fixed and mobile types.
The noise level can reach below 80 dB(A).
This kind of power station has good mobility, strong adaptability and rapid power supply. It is suitable to be used in densely populated areas or where the environmental noise is strictly required. For example, studio, star-rated hotels, office building, scientific research institution, hospital, and universities and colleges, etc.
1. Low noise, overall compact structure, little space occupation;
2. The box body is detachable structure, it is made of steel plate, and the surface is coated with high performance antirust paint; Meanwhile,it is with noise reduction and rainproof function.
3. The inside of the boby adopts multilayer barrier impedance mismatch noise elimination structure and built in large impedance silencer.
4. The box body structure design is reasonable; A large capacity oil tank is arranged inside the body; At the same time, two inspection doors are arranged at the left and right side of the body in order to facilitate the genset troubleshooting.
5. At the same time, the observation window and the emergency stop button are set on the box body so as to observe the running state of the genset as well as stop the machine at the fastest speed in case of emergency so as to avoid damage to the genset.
6. Bottom fuel tank for 8-12 hours operation